General Information
The DOORMASTER 4 universal adapter allows for connection
of 4 existent wired door intercoms to any TK-unit, provided the
existence of a A/B-interface. Already existing door stations can be
connected or the TK-unit can be integrated into a multi-family-house
door intercom unit.
You can connect up to 4 bell chime buttons. For every button a
different dial number can be programmed. Programming is realized
through a MFV-postfix which allows remote administration.
On pressing the bell chime button on the door station the unit will
occupy a line and dial a preset phone number consisting of 1 to 5
digits. On answering the call the extension is directly connected with
the door station. A MFV-postfix activates the door opener.
For further information please contact us!
Performance Features
- high-end speech controlled hands-free equipment
- busy tone detection
- volume control for microphone and loudspeaker
- contact controllable through MFV-postfix (door opening function)
- controlled disconnection through MFV-postfix
- external suppression of MFV-input
- connection to analog A/B-calling-partner-connection (bi-filar), adjustable MFW- or IWV-dialing
- hardware activation timer (adjustable)
- Up to 4 door bell chime buttons (12 VAC call voltage or dry
contact) can be connected. For each button one phone number with up to
5 digits (1-0, *, #) can be programmed
- programming through MFV-postfix
- programmable door opening time (0 to 9 seconds)
- suppressible automatic call answer function
- connection for external control relay (1471 or 1471E) to control video cameras or other functions
- 8 Vdc voltage output for TFE, activated through line seizure
- automatic line disconnection after door opening (programmable)
- external LED for line seizure connectable
Technical Data
- high-end speech controlled hands-free equipment
- power consumption: min. 18 mA, telephone line powered (min. 24 V, max. 60 V)
- stand-by power consumption: 4 µA
- power supply input: 12 Vac, max. 1 A (only for optional 8 Vdc output)
- power supply for TFE: 8 Vdc, max. 200 mA
- operating temperature: - 5° to + 45° C
- max. door opener contact load: 40 V, 2 A
- dimensions: 158 x 89 x 57 mm (b x t x h). DIN-railbox 9 DIN A units
- type approvals: CE